Aluminum Backed Abrasive Flap Disc Material Safety Data
Sheet (MSDS)
Section I
Manufacturer's Name: Weiler Corporation
Address: One Weiler Drive, Cresco, PA 18326
Emergency Telephone Number: (570) 595-7495
Telephone Number for Information: (570) 595-7495
Date prepared: January 6, 2012
Name of preparer: Frank Hettes
Section II - Hazardous Ingredients / Identity Information
Hazardous Components,
(Specific Chemical Identity, Common Name(s)
CAS#
OSHA PEL
*REG.
(Y/N)
ACGIH
TL
Carcinogen
(Y/N)
% (optional)
AL2O3 (Aluminum Oxide)
-
15mg/m3
-
5mg/m3
-
-
ZR O2 (Zirconium Oxide)
-
5mg/m3
-
5mg/m3
-
-
Epoxy Resin
(Based on a blend of Bisphenol-A & Bisphenol-F)
-
N.I.
-
N.I.
-
-
CACO3 (Calcium Carbonate)
-
N.I.
-
N.I.
-
-
Cotton
-
N.I.
-
N.I.
-
-
Section III - Physical / Chemical Characteristics Boiling Point: **N/A
Vapor Pressure (mm Hg.): **N/A
Vapor Density (AIR=1): **N/A
Solubility in Water: The paper label has slight water solubility
Specific Gravity (H2O=1): **N/A
Melting Point: **N/A
Evaporation Rate (Butyl Acetate=1): **N/A
Appearance and Odor: Solid aluminum disc coated with flaps of abrasive cloth; no odor.
Section IV - Fire and Explosion Hazard Data Flash Point (method used): **N/A
Flammable Limits: 200 degrees C LEL: **N/A UEL: **N/A
Extinguishing Media: Any standard extinguishing media (water, carbon dioxide, foam, dry chemical)
Special Fire Fighting Procedures: None
Unusual Fire and Explosion Hazards: None
Section V - Reactivity Data Stability: Stable
Conditions to avoid: **N/A
Incompatibility (Materials to Avoid): Strong alkali
Hazardous Decomposition or Byproducts: During use, grinding dust is generated.
Hazardous Polymerization: Will not occur
Conditions to avoid: Exposure to strong alkali
Section VI - Health Hazard Data
Primary Route(s) of Entry
Health Hazards
(Acute and Chronic)
First Aid and
Medical Information
Inhalation
May cause coughing, shortness of breath.
Remove to fresh air. Seek medical advice if chronic.
Ingestion
Ingestion very unlikely and not recommended.
Seek medical advice.
Skin
May cause abrasions.
Dust may cause skin irritation
Obtain First Aid.
Wash with soap and water.
Eyes
Dust may irritate eyes.
Wash with water. Seek medical advice.
Carcinogenicity: Not known
Section VII - Precautions For Safe Handling And Use Steps to be taken in case material is released or spilled: No special procedures; standard clean-up.
Waste disposal method: Standard landfill methods consistent with applicable Federal, State and Local laws.
Precautions to be taken in handling and storage: Handle with care, avoid impact; store dry at 20 degrees C+/- 20 C; 55-60% air humidity.
Other Precautions: Normal precautions for nuisance dust and particulates generated during grinding.
Section VIII - Control Measures Respiratory protection (specify type): Use approved respiratory protection for nuisance dust.
Ventilation:
Local Exhaust: Required
Mechanical (General): Recommended
Special: Respiratory protection
Other: **N/A
Protective gloves: Recommended
Eye protection: Mandatory
Other protective clothing or equipment: Hearing protection & face shield recommended; keep machine guards in place.
Work/Hygienic Practices: **N/A